Join Our Mailing List

Email:

   Products   |   Services  |   Support   |   Company  |   Resources  |   Shop Visix     

 

Display Device Management & Control


 

This integrated device control solution embeds Simtrol's OnGuard technology into Visix's Web-based content creation, management and delivery application. Through a custom tailored interface, Visix administrators can now manage the content being delivered and the display devices showing the message.

The advantages of combined Visix and Simtrol technologies eliminates the challenge faced in virtually every digital signage implementation to date - the inability to control and monitor endpoint displays. By automating shutdown in off hours, you can reduce the total cost of ownership of digital displays and extend their life. Assurances of content delivery is greatly improved, with email notification for display problems and reports to verify endpoint displays were on during scheduled times.


Display Device Control Specifications
Running on a Visix Content Server, Simtrol’s device control application enables IP based device control and management capabilities through a custom tailored interface. Visix application administrators can remotely monitor, control, schedule and diagnose displays and other devices.

Visix licenses device control to the individual display and not the Channel Player. Channel Players have no communication relationship or interaction with device control components.

With the Simtrol application on the Visix platform, the solution can easily expand to other devices. Optionally, users can add Simtrol’s OnGoer device control product to provide local control for any device via touch panels, LCD monitors or other displays. Click here to see Sample Interconnectivity Diagram.

 

Device Control Application Features (at large)

  • IR, IO, IP, USB, serial and other device control

  • Pre-configured control interface

  • Power on/off

  • Source input

  • Volume

  • Mute on/off

  • Hour/Day/Week schedule

  • BASIC and Visual Basic graphical user interface development tools

  • Commodity PC hardware support

  • Diverse device control library

  • Configure sites utilizing drag-n-drop tools

  • Visual/audible/email device alarms

  • Programmable remote control panels

  • Customizable graphical site/device views

  • Device scheduling

  • Reporting tool for collecting device information

  • Powerful device diagnostic tools

Control Codes
The most reliable device control protocol is RS232. Some devices must be controlled via an IR (infrared) interface. Though Visix recommends devices utilizing RS232 control protocols, IR control is available for a nominal up charge. Simtrol maintains a growing library of device control codes on file at www.simtrol.com/reseller. You must be a registered Simtrol reseller to access this library. Alternatively, contact a Visix representative to confirm whether or not the device you need to control is on file.

If the control codes are not on file, Simtrol will either acquire or learn the codes and write the source for the user. Programmers may need access to the device via the Internet during the process. Clients should allow 10 business days for coding and debugging.
 

Software Maintenance
With the purchase of the device control option your will receive a software license that does not expire. However, Simtrol recommends that its software be covered by a maintenance program that entitles the customer to receive software updates and telephone support. If the client purchases a Software Maintenance and Support Agreement (SMA) from Visix to cover the Content Server, the same agreement covers the device control components. If a client chooses to add device control after they purchase the Content Server and associated SMA, there is a $30.00 per display charge to roll the displays into the Content Server SMA.
 

Control Interfaces
The standard wired interface (IP:RS232) offered with the AXIS-TV-DCO is manufactured by Precidia Technologies.
 

Serial Interface:

RS-232 DCE Interface

Serial Connector:

DB-9 Female

Serial Speed:

300 - 38400 bps (bursts to 115.2 kbps)

Ethernet Interface:

Ethernet II, IEEE 802.3, 10 Base-T

Ethernet Connector:

RJ-45

Ethernet Speed:

10 Mbps

Status LEDs Indicators:      

Power, Ethernet (link,collison,transmit) COM (serial) - transmit and status

Protocols Supported:

ARP, ICMP, UDP, TCP, IP

Network Services:

HTTP, Telnet, TFTP, Com Port Control (RFC2217), SNMPv2c, DHCP, IPSec (manually keyed)

Power Requirements:

9V DC external (can provide up to 350mA at 9V to end device)

Operating Temperature:  

0-50°C / 32-125°F

Dimensions:

1.75 (w) x 0.95 (h) x 3.33 in. (l)

Weight:

285 g (9.84 oz) (including power supply)

 

 

The wireless interface (IP:RS232) option is manufactured by Digi International.
 

Serial Interface:

Switch selectable RS-232/422/485

Serial Connector:

DB-9 Female

Serial Speed:

230-400 bps (7/8 data bits – 1/1.5/2 stop bits – none/even/odd parity

Wireless Interface:

Standard: IEEE 802.11b

Frequency:

2.4 GHz

Data rate:

Up to 11 Mbps with automatic fallback

Modulation:

CCK (11/5 Mbps), DQPSK (2 Mbps), DBPSK (1 Mbps)

Transmit power:

16 dBm typical

Receive sensitivity:

-82 dBm @ 11 Mbps

Antenna connector:

1 x RP-SMA

Wireless Security:

WEP (Wired Equivalent Privacy)
     - Dynamic WEP, LEAP (WEP only), PEAP
     - 64/128-bit encryption (RC4)
     - WPA/WPA2/802.11i
128-bit TKIP/CCMP encryption
802.1X EAP authentication
     - Dynamic WEP, LEAP (WEP only), PEAP,
     - EAP-TLS, EAP-TTLS
     - PEAP/MSCHAPv2, PEAP/TLS, PEAP/GTC,
     - PEAP/OTP,PEAP/MD5, EAP-TTLS/EAP-MD5,
     - EAP-TTLS/EAP-GTC, EAP-TTLS/EAP-OTP,
     - EAP-TTLS/EAP-MSCHAPv2, EAP-TTLS/EAP-TLS,
     - EAP-TTLS/MSCHAPv2, EAP-TTLS/MSCHAP,
     - EAP-TTLS/PAP, EAP-TTLS/CHAP
Enterprise and Pre-Shared Key (PSK) mode

Status LEDs Indicators:

Power, Network link and Activity

Power Requirements:

9-30 VDC external

Operating Temperature:     

 -200-65°C / 14-149°F

Dimensions:

1.68 (w) x 0.999(h) x 4.188 in. (l)

 

 

The IR interface (IP:IR) option is manufactured by Global Cache.
 

Serial Interface:

RS-232

Serial Connector:

DB-9 Female

Serial Speed:

19.2K baud bi-directional hardware flow

IR:

3.5mm mono jack, independent user selectable IR outputs or sensor inputs

Ethernet Interface:

Ethernet II, IEEE 802.3, 10 Base-T

Ethernet Connector:

RJ-45

Ethernet Speed:

10 Mbps

Status LEDs Indicators:     

Link, network activity, power, IR, and sensor activity

Protocols Supported:

TCP, IP

Network Services:

HTTP

Power Requirements:

12 to 18V DC@500mA (wall power adapter included)

 

 

Sample Interconnectivity Diagram

 

 

 

► Click here to download our AxisTV PDF

► Click here to download our DVM PDF

 

 

About Visix   |   Privacy   |   Copyright   |   Contact